- Electrical Safety Tutorial
- Electrical Safety - Home
- Power System
- Indian Standards
- Low Voltage Overload Protection
- Short Circuit Protection
- Earth Fault Protection
- Earthing
- Types of the Supply System
- Cables
- Classification of Hazard-Prone Areas
- Safety Measures Related to Gas/Ducts/Fibre material
- Classification of Temperature
- Protection Against Weather Complexities
- Safe Electrical Equipment Design Characteristics
- Test Certifications
- Procedure to Mark Unprotected Equipment
- Maintenance of Unprotected Equipment
- Duties and Obligations
- Primary Ex-protection
- Secondary Ex-Protection
- Precautions Against Highly Flammable Contents
- Safety Measures During Handling Lighting Protection Equipment
- Bonding
- Transformer Safety
- Motor Handling Safety
- Generator Handling Safety
- Crane Handling Safety
- Safety Measures During Preventive Maintenance
- Types of Safety Equipment
- Implications of Human Behaviour
- Do's and Don'ts at a Glance
- Electrical Safety Useful Resources
- Electrical Safety - Quick Guide
- Electrical Safety - Useful Resources
- Electrical Safety - Discussion
Electrical Safety - Short Circuit Protection
A short-circuit condition means a circuit allows the current to flow through an unintended path with very low electrical impedance. It is a direct contact between two points of different electric potential.
The short circuit protection system is broken down into the following systems −
Alternating Current System
- Phase to Ground contact
- Phase to Neutral contact
- Phase to Phase contact
- Contact between windings of an electrical machine in a phase
Direct Current System
- Pole to Ground contact
- Contact between two poles
There can be numerous causes resulting in the above type of contacts including damage to the insulation of conductors, loose, broken or stripped wires and cables, and deposition of conducting materials such as dust, moisture, etc.
Major Causes of Short Circuit
A sudden surge of current equals to hundred times of working current flows through the circuit. This leads to the damage of electrical equipment. The following two phenomena are responsible for the devastating effects of short circuits −
Thermal Phenomenon
This phenomenon refers to the energy released into the electrical circuit when short-circuiting current flows through the circuit. This thermal effect results in the causes of a short circuit −
Melting of the conductor contacts
Damage to insulation
Generation of electrical arcs
Destruction of the thermal elements in the bimetallic relay
Electro-dynamic Phenomenon
This phenomenon refers to the production of intensive mechanical stress when the current crosses and results in the following conditions −
- Breakage of the conductors
- Repulsion of contacts inside the contactors
- Distortion of conductors in windings
Short Circuit Protection Devices
To protect the devices and people from short circuit hazards, protecting devices are used in electrical circuits. These devices can detect the faults and trip the circuit immediately before the surge current reaches to the maximum.
There are two popular protecting devices used frequently in every electrical circuit.
Fuse
Fuse is operated once in the circuit and then must be replaced after the trip occurs. It is helpful for phase by phase (single pole) protection. It offers a high breaking capacity at low volume, which limits electro-dynamic stress.
Following images show different types of fuse −
Circuit Breaker
Circuit breakers can be reset either manually or automatically. It automathy breaks the circuit within a short cutoff time and separates the load from the power supply that protects the circuit from any damage. The magnetic triggers of CB open the poles. CBs limit both the thermal and thermodynamic effects. It works faster than a fuse. For example, Molded Case Circuit Breaker (MCCB), Molded Case Switch (MCS), Air/Oil/SF6/Vacuum Circuit Breaker (ACB/OCB/SCB/VCB).
The following images show different types of circuit breakers:
Characteristics of Short Circuit Protection Devices
We will now learn the different characteristics of short circuit protection devices. The characteristics are shown below −
Breaking Capacity
The maximum value of the estimated short circuit current that can enable the device to break the circuit at a given voltage is called the breaking capacity.
Closing Capacity
The maximum short circuit current that can enable the device to reach its rated voltage at specific condition is called the closing capacity. It is the rational multiple of breaking capacity.